Skip to main content

Table 1 Comparison of segmentation results between single and multi-path encoder

From: Multi-modality self-attention aware deep network for 3D biomedical segmentation

 

Dice

Sensitivity

Positive Predicted Value

WT

TC

ET

WT

TC

ET

WT

TC

ET

Single

0.8135

0.5900

0.7687

0.8451

0.6732

0.8003

0.8651

0.6751

0.8164

Multi (unshared)

0.7912

0.5338

0.6833

0.7999

0.6557

0.7591

0.8635

0.5723

0.7395

Multi (shared)

0.8063

0.5777

0.7503

0.8414

0.6192

0.7951

0.8557

0.6007

0.7820